5. Trouble and Troubleshooting
37
5. TROUBLE AND TROUBLESHOOTING
*Note: Other warning lamps do not go on when the switch is turned on. They only go on when there is an abnormality.
Trouble Probable Cause Measure
Reference
Alarm Buzzer and Alarm
Lamps On During
Operation
Shift to low speed operation immediately, and check which lamp has come on. Stop
the engine for inspection. If no abnormality is identified and there is no problem with
operation, return to port at your lowest speed and request repairs.
Eng.Lube Oil Press.
Warning Lamp goes on
Engine Lube Oil insufficient;
Fuel filter clogged.
Check Lube Oil Level.
Replenish or replace.
3.2.2
4.3.1(1)
*Water proof warning lamp
goes on
Breakage of seal mount on the sail drive. Check and change the rubber
mount.
Faulty Warning Devices
Do not operate the engine if alarm devices are not repaired.
Serious accidents may result if difficulties are not spotted due to faulty alarm lamps.
When switch is turned ON:
Alarm buzzer does not sound. Circuit broken or buzzer defective. Ask for repairs.
Warning lamps do not go on Eng. Lube Oil Press.
Seawater.
No current available.
Circuit broken or lamp burnt out.
Ask for repairs.
One of the warning lamps
does not go out
Sensor switches faulty. Ask for repairs.
Charge lamp does not go out
during operation
V-belt is loose or broken.
Battery defective.
Alternator power generator failure.
Replace V-belt; adjust tension.
Check fluid level, specific gravity;
replace.
Ask for repairs.
4.3.4(3)
4.3.2(4)
002550-00E
002550-00E